The importance of supervised monitoring modules utilized in control and monitoring of extinguishing systems

In many places from chemistry laboratories to industrial services, so as to guarantee the security of life and property towards a potential hearth hazard, extinguishing methods are used along with detection and alarm systems. It can be extraordinarily essential that the extinguishing techniques installed may be triggered by the fireplace extinguishing control panel, so as to get rid of a possible hearth with early intervention.
In order to fulfill these wants, and with 35 years of sectoral data and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working according to the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote performance of the indicators and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be began manually and remotely; and
to guarantee that the extinguishing course of may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced utilizing surface-mount know-how and are aimed at making the automation of the extinguishing system and fireplace and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by always considering the needs of the set up. In เครื่องมือที่ใช้วัดความดันเลือด that require the integration of the extinguishing system with the clever addressable fireplace detection system, it provides solutions via the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring เกจวัดอาร์กอน play an necessary position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or quick circuit within the wiring between the contact monitoring modules and the peripheral techniques could cause disruption of the triggering, with probably important penalties. For this purpose, when choosing monitoring modules, it must be taken into account that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable hearth detection and alarm control panels are continually speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to observe conditions similar to open circuits and brief circuits that may happen in the system. Many duties can be carried out in the fireplace extinguishing set up, such because the control and monitoring of all valves that may interrupt the move of water, water flow alarm switches, strain switch, and electrical or diesel fire pumps.
By including two contact monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to regulate the fireplace scenario, monitoring and control of the extinguishing system by way of an clever addressable fire detection and alarm system could be performed effectively.
For more info, go to www.mavili.com.tr/en
Share

Scroll to Top