Preventing Water Hammer With Variable Speed Actuators

Water hammer is usually a main concern in pumping systems and should be a consideration for designers for several causes. If not addressed, it can cause a bunch of issues, from broken piping and helps to cracked and ruptured piping parts. At worst, it might even cause damage to plant personnel.
What Is Water Hammer?
Water hammer occurs when there’s a surge in stress and move fee of fluid in a piping system, inflicting speedy changes in stress or force. High pressures may find yourself in piping system failure, corresponding to leaking joints or burst pipes. Support parts can even experience robust forces from surges or even sudden move reversal. Water hammer can occur with any fluid inside any pipe, however its severity varies relying upon the situations of both the fluid and pipe. Usually this happens in liquids, but it could additionally happen with gases.
How Does Water Hammer Occur & What Are the Consequences?
Increased เกจแรงดันสูง occurs each time a fluid is accelerated or impeded by pump situation or when a valve place adjustments. Normally, this pressure is small, and the rate of change is gradual, making water hammer virtually undetectable. Under some circumstances, many kilos of strain may be created and forces on helps could be great enough to exceed their design specifications. Rapidly opening or closing a valve causes stress transients in pipelines that can outcome in pressures nicely over regular state values, causing water surge that can critically injury pipes and course of control equipment. The significance of controlling water hammer in pump stations is well known by utilities and pump stations.
Preventing Water Hammer
Typical water hammer triggers embrace pump startup/shutdown, power failure and sudden opening/closing of line valves. A simplified model of the flowing cylindrical fluid column would resemble a metal cylinder suddenly being stopped by a concrete wall. Solving these water hammer challenges in pumping techniques requires both lowering its results or preventing it from occurring. There are many options system designers need to bear in mind when creating a pumping system. Pressure tanks, surge chambers or related accumulators can be used to absorb stress surges, that are all useful tools in the fight in opposition to water hammer. However, stopping the strain surges from occurring in the first place is often a greater strategy. This can be achieved by utilizing a multiturn variable speed actuator to regulate the velocity of the valve’s closure rate at the pump’s outlet.
The development of actuators and their controls provide alternatives to make use of them for the prevention of water hammer. Here are three cases the place addressing water hammer was a key requirement. In all cases, a linear attribute was important for flow control from a high-volume pump. If this had not been achieved, a hammer effect would have resulted, potentially damaging the station’s water system.
Preventing Water Hammer in Booster Pump Stations
Design Challenge
The East Cherry Creek Valley (ECCV) Southern Booster Pump Station in Colorado was fitted with high-volume pumps and used pump verify valves for move management. To avoid water hammer and probably serious system damage, the appliance required a linear circulate characteristic. The design challenge was to acquire linear move from a ball valve, which usually exhibits nonlinear move characteristics as it is closed/opened.
Solution
By using a variable pace actuator, valve position was set to realize totally different stroke positions over intervals of time. With this, the ball valve might be driven closed/open at varied speeds to realize a more linear fluid circulate change. Additionally, within the occasion of a power failure, the actuator can now be set to shut the valve and drain the system at a predetermined emergency curve.
The variable speed actuator chosen had the potential to regulate the valve place primarily based on preset occasions. The actuator might be programmed for up to 10 time set factors, with corresponding valve positions. The speed of valve opening or closing might then be controlled to ensure the desired set place was achieved at the correct time. This superior flexibility produces linearization of the valve traits, allowing full port valve choice and/or considerably decreased water hammer when closing the valves. The actuators’ integrated controls have been programmed to create linear acceleration and deceleration of water during normal pump operation. Additionally, within the occasion of electrical energy loss, the actuators ensured fast closure via backup from an uninterruptible energy supply (UPS). Linear circulate price
change was additionally offered, and this ensured minimal system transients and easy calibration/adjustment of the speed-time curve.
Due to its variable pace functionality, the variable velocity actuator met the challenges of this installation. A travel dependent, adjustable positioning time provided by the variable pace actuators generated a linear circulate through the ball valve. This enabled fantastic tuning of operating speeds by way of ten totally different positions to forestall water hammer.
Water Hammer & Cavitation Protection During Valve Operation
Design Challenge
In the area of Oura, Australia, water is pumped from a quantity of bore holes into a collection tank, which is then pumped into a holding tank. Three pumps are every equipped with 12-inch butterfly valves to control the water flow.
To defend the valve seats from injury caused by water cavitation or the pumps from operating dry within the occasion of water loss, the butterfly valves should be capable of fast closure. Such operation creates huge hydraulic forces, known as water hammer. These forces are enough to trigger pipework damage and should be avoided.
Solution
Fitting the valves with part-turn, variable speed actuators allows totally different closure speeds to be set during valve operation. When closing from fully open to 30% open, a fast closure rate is ready. To avoid water hammer, in the course of the 30% to 5% open part, the actuator slows down to an eighth of its earlier velocity. Finally, in the course of the ultimate
5% to complete closure, the actuator speeds up once more to reduce cavitation and consequent valve seat damage. Total valve operation time from open to close is around three and a half minutes.
The variable velocity actuator chosen had the capability to vary output speed based mostly on its place of travel. This advanced flexibility produced linearization of valve characteristics, permitting less complicated valve selection and decreasing water
hammer. The valve speed is defined by a most of 10 interpolation factors which could be precisely set in increments of 1% of the open position. Speeds can then be set for up to seven values (n1-n7) based on the actuator kind.
Variable Speed Actuation: Process Control & Pump Protection
Design Challenge
In Mid Cheshire, United Kingdom, a chemical firm used a number of hundred brine wells, every using pumps to switch brine from the properly to saturator items. The circulate is controlled utilizing pump delivery recycle butterfly valves pushed by actuators.
Under regular operation, when a decreased flow is detected, the actuator which controls the valve is opened over a period of 80 seconds. However, if a reverse move is detected, then the valve must be closed in 10 seconds to guard the pump. Different actuation speeds are required for opening, closing and emergency closure to make sure safety of the pump.
Solution
The variable velocity actuator is ready to present as a lot as seven different opening/closing speeds. These could be programmed independently for open, shut, emergency open and emergency close.
Mitigate Effects of Water Hammer
Improving valve modulation is one answer to consider when addressing water hammer issues in a pumping system. Variable pace actuators and controls provide pump system designers the flexibility to repeatedly management the valve’s working velocity and accuracy of reaching setpoints, another process other than closed-loop control.
Additionally, emergency protected shutdown can be offered utilizing variable speed actuation. With the capability of continuing operation utilizing a pump station emergency generator, the actuation expertise can offer a failsafe option.
In other words, if a power failure happens, the actuator will close in emergency mode in varied speeds using power from a UPS system, allowing for the system to empty. The positioning time curves could be programmed individually for close/open course and for emergency mode.
Variable pace, multiturn actuators are additionally an answer for open-close obligation situations. This design can present a soft start from the beginning position and soft cease upon reaching the tip place. This level of control avoids mechanical stress surges (i.e., water hammer) that may contribute to untimely component degradation. The variable pace actuator’s capacity to supply this control positively impacts upkeep intervals and extends the lifetime of system components.
Share

Scroll to Top